222 P9 ASD Installation and Operation Manual
Communications Option (DeviceNet/Profibus) Setting 12
Program Communications Communication Settings
See F841 for information on this parameter.
Direct Access Number — F845
Parameter Type — Selection List
Factory Default 0000h
Changeable During Run — Yes
Communications Option (DeviceNet/Profibus) Setting 13
Program Communications Communication Settings
See F841 for information on this parameter.
Direct Access Number — F846
Parameter Type — Selection List
Factory Default 0000h
Changeable During Run — Yes
Disconnection Detection Extended Time
Program Communications Communication Settings
This parameter is used to set the length of time that no communications activity
may exist before the communications link is disconnected.
Direct Access Number — F850
Parameter Type — Numerical
Factory Default 0.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 100.0
Units — Seconds
ASD Operation at Disconnect
Program Communications Communication Settings
This parameter is used to set the P9 ASD action to be carried out in the event of
the loss of communications.
Settings:
0 — Stop and Terminate Communication
1 — Do Nothing (Continue Programmed Operation)
2 — Deceleration Stop
3 — Coast Stop
4 — Emergency Off
5 — Preset Speed (Setting of F852)
Direct Access Number — F851
Parameter Type — Selection List
Factory Default Stop and Terminate
Communication
Changeable During Run — Yes
Preset Speed Operation Selection
Program Communications Communication Settings
This parameter setting is used to set the Preset Speed selection to be used if
Preset Speed is selected at
F851.
Settings:
0 — Disabled
1 – 15 — Preset Speed Number
Direct Access Number — F852
Parameter Type — Selection List
Factory Default 0 (Disabled)
Changeable During Run — Yes
Communications Option Station Address Monitor
Program Communications Communication Settings
This parameter is used in the setup of the communications network by reading
the Media Access Code (MAC) address of the ASD that is connected to a node
of the communications system.
The MAC Address is set via DIP switches of the optional device.
See the DeviceNet Option Instruction Manual (P/N 58683) for additional
information on this parameter.
Direct Access Number — F853
Parameter Type — Selection List
Factory Default 0 (Disabled)
Changeable During Run — Yes
Minimum — 0
Maximum — 255
F845 F853