– 3 –
FILE NO. SVM-04004
MODEL RAS-13UKHP-E3 / RAS-13UAH-E 3 RAS-13UKP-E3 / RAS-13UA-E3
ITEM Cooling Heating Cooling
Capacity
220 V 240 V 220 V 240 V 220 V 240 V
kW 3.55 3.60 4.40 4.45 3.70 3.75
Phase 1Æ
Power source V 220 - 240
Hz 50
Power consumption kW 1.27 1.32 1.26 1.33 1.24 1.28
Power factor % 98 96 98 96 98 95
Running Indoor A 0.15
current Outdoor A 5.75 5.60 5.70 5.65 5.75 5.60
Starting current A 25 24
Moisture removal lit/h 2.0
Noise
Indoor (H/M/L) dB 41/35/31
Outdoor (220 - 240 V) dB 49 51 49 51 47 48
Refrigerant
Name of refrigerant R22
Rated amount kg 1.00 0.80
Refrigerant control Capillary tube
Gas side size mm Æ12.7
Connection type Flare connection
Liquid side size mm Æ6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
1
(One way)
Maximum height
difference
INDOOR UNIT RAS-13UKHP-E3 RAS-13UKP-E3
Height mm 275
Dimensions Width mm 790
Depth mm 208
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 630 650 630
Air volume Medium fan m
3
/h 520 550 520
Low fan m
3
/h 430 490 430
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-13UAH-E3 RAS-13UA-E3
Height mm 550
Dimensions Width mm 780
Depth mm 270
Net weight kg 37 34
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 2120
2200
2120 2200 2030 2150
Fan motor output W
42
Compressor
Model PH170T2-4L2 PH225X2C-4FT
Output W 1100
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 -10 ~ 24 15 ~ 43
1. SPECIFICATIONS
m
m
6
30
15*

Table of Contents