EasyManua.ls Logo

Toshiba RAS-10KHP-E3 - Outdoor Unit Does Not Operate

Toshiba RAS-10KHP-E3
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
61
FILE NO. SVM-04004
Check items as following procedure
in 9-5-4, 9-5-5, 9-5-6
9-5-3. Outdoor unit does not operate
Shut off the power supply
from AC outlet once and turn
it on after 5 seconds.
See "Power can not be turned on".
NO
NO
NO
NO
YES
YES
YES
YES
Does the power turn on by pushing
the [START/STOP] button of the
remote control?
Is AC 220-240V supplied between
terminal block 1 -
2
?
Relays (RY01) or IC31
or IC30 is failure.
Replace the
P.C. board.
Is cable connection between indoor
and outdoor units correct?
Correct cabling between indoor
and outdoor units.
Does the OPERATION lamp blink?
See "Power can not be turned on".
RAS-13UKP-E3, RAS-10UKP-E3, RAS-07UKP-E3, RAS-13UKPX3, RAS-12UKPX3, RAS-10UKPX3, RAS-07UKPX3