– 5 –
FILE NO. SVM-04004
RAS-07UKHP-E3 RAS-07UKP-E3 RAS-07UKPX3
RAS-07UAH-E3 RAS-07UA-E3 RAS-07UAX3
ITEM Cooling Heating Cooling Cooling
Capacity
220V 240V 220V 240V 220V 240V 220V 240V
kW 2.00 2.05 2.20 2.25 2.10 2.15 2.10 2.15
Phase 1∅
Power source V 220 − 240
Hz 50
Power consumption kW 0.69 0.76 0.60 0.65 0.60 0.64 0.60 0.64
Power factor % 98 97 97 95 92 89 92 89
Running Indoor A 0.15
current Outdoor A 3.05 3.10 2.65 2.70 2.80 2.85 2.80 2.85
Starting current A 13 11
Moisture removal lit/h 0.8
Noise Indoor (H/M/L) dB 38/32/26
Outdoor (220-240V) dB
Refrigerant
Name of refrigerant R-22
Rated amount kg 0.62 0.57
Refrigerant control Capillary tube
Gas side size mm 9.52
Connection type Flare connection
Liquid side size mm 6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
m 10*
1
(One way)
Maximum height
m  5
difference
INDOOR UNIT RAS-07UKHP-E3  RAS-07UKP-E3  RAS-07UKPX3
Height mm 275
Dimensions Width mm 790
Depth mm 208
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 570 610 570
Air volume Medium fan m
3
/h 460 490 460
Low fan m
3
/h 340 400 340
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-07UAH-E3 RAS-07UA-E3 RAS-07UAX3
Height mm 530
Dimensions Width mm 660
Depth mm 240
Net weight kg 27 26
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume  m
3
/h 1280 1360 1280 1360 1280 1360 1280 1360
Fan motor output W 20
Compressor
Model PH80T1-4C
Output  W 605
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 −10 ~ 24 15 ~ 43
 MODEL
44
45 45
46
44 45
44
45