CIX40 Installation
CIX40 Installation
Site Requirements
Strata CIX40 Installation & Maintenance 5/06 1-9
Table 1-2 provides a summary of the electrical and environmental characteristics.
Table 1-2 Summary of Electrical/Environmental Characteristics
CIX40 Primary Power
Input AC (Power Supply Specification)
AC frequency
Power
AC input current
105~125VAC
50/60 Hz
CIX40 - 100 watts maximum
1.5A maximum (100 VAC)
Environmental Specifications
Operating temperature
Operating humidity
Storage temperature
32~104° F (0 ~40° C)
20~80% relative humidity without condensation
-4~140° F (-20~60° C)
Power
Input DC 15V use the factory-shipped AC adapter
Power Converter
DC voltage output specification
-24VDC (-26.3 ~ -28.3VDC)
+5VDC (+4.5 ~ +5.5VDC)
Standard Telephone Ring Circuit (GMAU2 and GSTU1)
Ring Voltage 180V p-p square wave
Ringing capability 1 REN, 1 circuit - one telephone per circuit

Other manuals for Toshiba Strata CIX40