CIX40 Installation
CIX40 Installation
Installing the CIX40 Cabinet
Strata CIX40 Installation & Maintenance 5/06 1-17
Step 2: Set Jumpers on the GMAU2 (Motherboard)
The GMAU2 (shown in Figure 1-14) supports up to 6 CO lines with Caller ID (CLID).
Figure 1-14 GMAU2 PCB
Table 1-5 GMAU2 Controls, Switches and Indicators
Control/Indicator/
Connector
Type of Component Description
SW1 2-position slide switch
Power Switch:
[STANDBY] = no DC power supply.
[ON] = DC voltage supplied. [ON]
activates the reserve power from HPFB-6
battery pack.
SW400
2-position slide switch 3dB Pad switchSW500
SW600
CD6 LED
Power indicator;
Lit when SW1 is [ON], turned on and AC
power or Reserve power is present.
Dark when SW1 is [STANDBY], turned off.
TB1 Terminal with screw Grounding for HPFB-6 external battery
TB3 Terminal with screw
Grounding for CIX40 system, connect to
earth ground
7113
SW1
ON/OFF
(Standby)
SW400
(3db/0dB)
SW500
(3db/0dB)
SW600
(3db/0dB)
3db 0dB
CO1
TB2
P8
TB3
CO2
CO3
P6
P5
P7
P4
ON
STANDBY
SW1