EasyManua.ls Logo

Toshiba Strata CIX40 - Getting Started; User Tutorial and Initial Setup

Toshiba Strata CIX40
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CIX40 Installation
CIX40 Installation
Installing the CIX40 Cabinet
Strata CIX40 Installation & Maintenance 5/06 1-19
Step 3: Install the GVPH1 Voice Mail PCB (optional)
The GVPH1 does not require a license.
1. In the CIX40 cabinet, remove the two screws and the GVPH1 stopper (Figure 1-17).
2. On the GVPH1, set the SW6 battery jumper to ON and set the Greeting language switch
(Figure 1-15). Default language is “English.” See Table 1-7 for other language settings.
3. Turn off system power. If the GCTU2 is installed remove it before installing the GVPH1.
4. Install the GVPH1 into the lower slot of the GMAS (sub-motherboard) (see Figure 1-12 and
Figure 1-17).
5. Install the GCTU2.
6. Replace the GVPH1 stopper and secure with the oridginal two screws.
7. Turn system power on.
Note To program GVPH1, refer to Strata CIX40 Voice Processing Programming Manual and use
UADM2 software.
!
To restore the GVPH1 to the data that was stored on the GVPH1 on board RAM (see
CAUTION! below)
1. Turn off CIX40 system power and uninstall GCTU2 and GVPH1.
2. Remove the GVPH1 battery jumper for two minutes.
3. Place the GVPH1 battery jumper back to the ON position, then install the GVPH1 and GCTU2.
4. Turn system power on.
CAUTION! Initializing the GVPH1 will over-write all Names, Security codes and saved
Messages with the data last saved to the on-board RAM during the last
Backup. If the database was never backed up, the factory default data will
be restored.
Note A GVMU database can not be restored to a GVPH.
Figure 1-15 GVPH1 Card
Battery Jumper
Located near the edge of the AMDS1 on the GVPH1.
CH4
CH3
CH2
CH1
SW1 - Language Selection Switch
Status

Other manuals for Toshiba Strata CIX40