INTERFACE MANUAL
Designation SVOFF (Servo OFF)
Input terminal CN6–34 pin
Exclusive signal
name used in the
controller
261
Signal logic
Signal judgment
Signal terminal
ON
(Servo OFF)
OFF
(Normal)
Open O
Short-circuit
O
Function Used to turn off the servo driver main power from the external
equipment.
While this signal is open, the servo power is turned off.
This signal can always be used, irrespective of the master
mode selected by means of the MODE switch.
Signal timing
EX_SVON (I)
SV_RDY (O)
SVOFF (I)
A
pprox. 1 sec.
Cautions 1. While this signal is open, the servo power cannot be
turned on in any mode.
2. Unless this signal is used, short-circuit between CN6–18
and CN6–34.
STE 71367
– 57 –