9. Troubleshooting guide
M/S
Sliding gate operator PULL T8, -T10, -T15 / Master-Slave
Error Possible reason Solution
display: „Stop-button released“
stop-button not connected or not
bridged
stop-button (Kl. ) connect or bridge >
use status display for help
display: „Photocell released“ photocell interrupted
check correct connection hence
remove obstacle > use status dispaly
for help
display: „Main safety sensing edge
released““
main safety edge interrupted or hot-
wired
check correct connection hence
remove obstacle > use status dispaly
for help
display: „Side safety sensing edge
released“
side safety sensing edge interrupted or
hot-wired
check correct connection hence
remove obstacle > use status dispaly
for help
display: „AR-System released“
gate ran into an obstacle or is too hard
to move
check adjustment of forces, remove
obstacle hence check if gate is easy
to move
display: „photocell
test negative“
interruption or hot-wired photocell
check correct connection hence
remove obstacle > use status dispaly
for help
display: „main safety edge
test negative“
(only when using the TX 310)
short-circuit or interruption of main
safety edge
check correct connection hence bat-
terry status of transmitter > use status
dispaly for help
display: „side safety edge
test negative“
(only when using the TX 310)
short-circuit or interruption of side
safety edge
check correct connection hence bat-
terry status of transmitter > use status
dispaly for help
display: „Low Voltage“ undervoltage check supply line
display: „Error PULL T8 (T10) Slave“
the slave operator caused an error
during the system check of main and
side sensing edges
check correct connection of side sens-
ing edge hence remove obstacle > use
status dispaly for help
no reaction when giving an impulse
no line voltage hence
safety fuse broken
check line voltage as well as safety
fuses
error of transmitter/control device/im-
pulse button,
e.g. transmitter not programmed
check transmitter/control device,
e.g. program transmitter and
check battery