- 12 - tousek / EN_PULL-T8-T10-T15-M-S_02 / 25. 03. 2020
• Before starting the programming, please choose the language. Use the buttons
+
or - to choose menu
language and conrm with .
• The language must be set in the master and in the Slave control board.
Note: Language selection can also be chosen by pressing the ESC button (
) for 5s, from any posi-
tion in menu.
• The program menu of the MASTER control is divided into “BASIC SETTINGS” and “MENU CONTROL”
• The program menu of the SLAVE control includes only the “MAIN MENU”.
The dierent menu points are indicated as follows:
= selectable settings = factory settings = status display
G
shows the menu points which are in the “ BASIC SETTINGS”
BASIC SETTINGS
• When entering the programming of the control unit for the rst time you will see the BASIC SETTINGS
(see initial operation page 27).
• Here the necessary adjustments which are necessary for the use of the operator/gate can be set quickly.
• For advanced settings/programming please choose the menu point “menu (control)”.
MAIN MENU
• For futher programming you will reach immediatly the MENU (CONTROL) (Basis settings are skipped)
• The menu control includes all kinds of settings, whereas in the slave control board only a part of the menu options
described in the menu structure ( see page 13) can be selected (marked with “M / S”).
All other functions are taken over by the master!!
Programming buttons
Programming menu Adjustments/overwiev
3.2 Adjustments - overview Sliding gate operator PULL T8, -T10, -T15 / Master-Slave
A
T
• For programming please remove cover (A) of control
device (loosen 2 bolts).
• The text display (T) informs you ou about operating status,
chosen menus and the adjustment of various parameters..
• The programming of the control is carried out with the help
of four buttons (
+
, -
, (=Enter) and (=Escape).
• Scrolling through the available menu points (up/
down) or the adjustment of a parameter (value in-
crease/decrease) is carried out with buttons + and –..
AUTO-COUNT: when holding one of the buttons the value
changes automatically.
• When pressing the
-button a conrmation for entering
the shown menu point, resp. for accepting the shown value
of a parameter is given.
• When pressing the
-button you return to the superior
menu point. Possibly changed adjustments of a parameter
are rejected with this button (the former values will remain).
• AUTO-EXIT: if no button is pressed during 1 min. then the
menu switches automatically to the “ready” menu (wihtout
saving changed parameters).