Configuration Guide     490
Configuring PoE PoE Power Management Configurations
System Power 
Consumption
Displays the real-time system power consumption of the PoE switch.
System Power 
Remain
Displays the real-time system remaining power of the PoE switch.
2)  In the Port Config section, select the port you want to configure and specify the 
parameters. Click Apply.
PoE Status Enable or disable the PoE function for on corresponding port. The port can supply 
power to the PD when its status is enable.
PoE Priority Select the priority level for the corresponding port. When the supply power 
exceeds the system power limit, the switch will power off PDs on low-priority 
ports to ensure stable running of other PDs.
Power Limit 
(0.1w-30.0w)
Specify the maximum power the corresponding port can supply. The following 
options are provided:
Auto: The switch will allocate a value as the maximum power that the port can 
supply automatically.
Class1: The maximum power that the port can supply is 4W.
Class2: The maximum power that the port can supply is 7W.
Class3: The maximum power that the port can supply is 15.4W.
Class4: The maximum power that the port can supply is 30W.
Manual: Enter a value manually.
Time Range
Select a time range, then the port will supply power only during the time range. For 
how to create a time range, refer to 
Time Range Function Configurations
.
PoE Profile
A quick configuration method for the corresponding ports. If one profile is 
selected, you will not be able to modify PoE status, PoE priority or power limit 
manually. For how to create a profile, refer to 
Configuring the PoE Parameters 
Using the Profile
.
Power(w)
Displays the port’s real-time power supply.
Current(mA)
Displays the port’s real-time current.
Voltage(v)
Displays the port’s real-time voltage.
PD Class
Displays the class the linked PD belongs to.
Power Status
Displays the port’s real-time power status.