Managing System System Info Configurations
Configuration Guide  
  29
Recurring Mode If you select Recurring Mode, specify a cycle time range for the Daylight Saving 
Time of the switch. This configuration will be used every year.
Offset: Specify the time to set the clock forward by.
Start Time: Specify the start time of Daylight Saving Time. The interval between 
start time and end time should be more than 1 day and less than 1 year(365 days).
End Time: Specify the end time of Daylight Saving Time. The interval between 
start time and end time should be more than 1 day and less than 1 year (365 days).
Date Mode If you select Date Mode, specify an absolute time range for the Daylight Saving 
Time of the switch. This configuration will be used only one time.
Offset: Specify the time to set the clock forward by.
Start Time: Specify the start time of Daylight Saving Time. The interval between 
start time and end time should be more than 1 day and less than 1 year(365 days).
End Time: Specify the end time of Daylight Saving Time. The interval between 
start time and end time should be more than 1 day and less than 1 year (365 days).
3)  Click Apply.
2.2  Using the CLI
2.2.1  Viewing the System Summary
On privileged EXEC mode or any other configuration mode, you can use the following 
command to view the system information of the switch:
show interface status [ fastEthernet 
port
 | gigabitEthernet 
port
 | ten-gigabitEthernet 
port
 ]
View status of the interface.
port
: Enter the number of the Ethernet port.
show system-info
View the system information including system Description, Device Name, Device Location, System 
Contact, Hardware Version, Firmware Version, System Time, Run Time and so on.
The following example shows how to view the interface status and the system information 
of the switch.
Switch#show interface status
 Port            Status            Speed   Duplex   FlowCtrl    Jumbo       Active-Medium
 -------         -----------     -----        ------       --------       ---------      -------------
 Gi1/0/1      LinkDown    N/A          N/A           N/A            Disable      Copper
 Gi1/0/2      LinkDown    N/A          N/A           N/A            Disable      Copper