Configuration Guide 732
Configuring SNMP & RMON Configuration Example
Figure 6-2  Enabling SNMP
2) Choose SNMP > SNMP Config > SNMP View to load the following page. Name the
SNMP view as View, set MIB Object ID as 1 (which means all functions), and set the view
type as Include. Click Create.
Figure 6-3 SNMP View Configuration
3) Choose SNMP > SNMP Config > SNMP Group to load the following page. Create a
group with the name of nms-monitor, choose SNMPv3 and enable authentication and
privacy, and add View to Read View and Notify View. Click Create.