General Settings Administration
44
Update the software for the entire headend installation
(including input/output modules) if this is not the case.
MAC addresses
Current/minimum/maximum temperatures
Power supply
Duplicated PIDs
Selecting IP services for output may result in a selection of services from
an MPTS stream that uses the same PID for two or more services.
It is not possible to output services with identical PIDs.
If you have selected services with identical PIDs, the System icon of the
headend unit that handles the output of the services with identical PIDs
turns red.
Click the affected unit to open the System information for unit
window.
The System information for unit window lists the output module(s)
and channel(s) which attempt to output services with identical PIDs.
To solve the problem you have to open the configuration window of the
output module(s) listed in the System information for unit window, and
deselect the selected IP services one by one while checking the System
information for unit window until the message disappears from the
window.