4
INTRODUCTION
Please read this book thoroughly and familiarise yourself with all instructions before
commencing installation.
Please keep it for future reference.
The shower installation MUST be carried out by a suitably qualified person, in the sequence of this
fitting instruction.
ADVICE TO USERS
Important: When first installed the unit will be empty. It is essential the unit should contain water
before the elements are switched on. It is vital that the commissioning procedure is followed. Failure to
carry out this operation will result in damage to the unit and will invalidate the guarantee.
The following points will help you understand how the shower operates:
a) Temperature/ow rate
The temperature control can be adjusted to provide shower temperatures between 30°C and
43°C.
Alternatively, the maximum temperature can be restricted to 41°C or BEAB Care by adjusting the
temperature stop mechanism inside the unit.
Important
: To comply with BEAB Care mark requirements the unit must not be able to run
hotter than 41°C (this is used when in healthcare or special needs environments).
The Omnicare SR Pumped unit is factory set at 43°C (nominal), see page 22 on how to
adjust the MAXIMUM temperature to 41°C.
At a selected showering temperature the unit will provide the optimum flow rate possible.
Note the flow rate for any showering temperature will be greater in the summer than in the winter
because of the variance in the ambient mains water supply temperature.
b) Temperature stabilisation
The shower will maintain temperature in accordance with the BEAB Care mark.
DO NOT place items such as soap or shampoo bottles on top of the unit. Liquid could seep through the
joint between the cover and backplate and possibly damage the sealing rubber.
IT IS ADVISED THAT WHERE THE PROPERTY IS LEFT UNATTENDED FOR
AN EXTENDED PERIOD OF TIME, THAT THE WATER AND ELECTRICITY
SUPPLIES TO THE SHOWER ARE ISOLATED.
PRODUCT FICHE
Model 8.5kW
Load Profile XS
Energy Efficiency Class A
Energy Efficiency (%) 39
Annual Electricity Consumption (kwh) 474
Sound Power Level (db) 56

Other manuals for Triton Omnicare

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Triton Omnicare and is the answer not in the manual?

Triton Omnicare Specifications

General IconGeneral
TypeElectric Shower
Temperature ControlThermostatic
Water Connection15mm compression
Start/Stop ButtonYes
MaterialPlastic
FinishWhite
Installation TypeWall Mounted
Warranty2 years
Water Entry PointsBottom
Cable Entry PointsBottom Entry
ApprovalsWRAS

Related product manuals