7
SPECIFICATION
ELECTRICAL
Product GEOSRP81 XEOSRP81
Nominal Power Rating at 230V 7.8kW 8.5KW
Nominal Power Rating at 240V
8.5kW N/A
Supply Fuse/Miniature Circuit Breaker
(MCB)
8.5kW - 40Amps
Residual Current Device (RCD) 30mA
Isolation Switch 45Amp double pole isolating switch, with 3mm
minimum contact gap
Supply Cable Maximum is 16mm, refer to Electrical Requirements
section
PLUMBING (see page 10 for plumbing requirements)
Supply Source Gravity fed cold water only
Minimum Dynamic Pressure and flow to
the inlet of the shower
8kPa (0.08 bar) at 8 litres per minute
Minimum head height 8cm
Maximum Static Pressure 100 kPa (1 bar)
Maximum inlet temperature 28°C (20°C BEAB Care)
Minimum inlet temperature 2°C (5°C BEAB Care)
Inlet connection 15mm diameter
Outlet connection ½” BSP male thread
MATERIALS
ABS Backplate, cover, controls, shower head
Minerally insulated corrosion resistant
metal sheathing
Elements
STANDARDS and APPROVALS
Splashproof rating IP25
Safety Complies with the requirements of current British and
European safety standards for household and similar
electrical appliances
BEAB Care Complies with the requirements of the BEAB Care mark
UKCA/CE Meets with Conformity Assessment for both UK and EU
Markets