EasyManuals Logo

Triton VELINO User Manual

Triton VELINO
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
Bar Mixer Shower
12
Important
The mixer shower has a temperature stop
to prevent accidental rotation to higher
temperatures. This is adjustable to provide a
maximum temperature of 35°C – 46°C.
The mixed water temperature can be adjusted
from cold through to a top limit (which can
be pre-set during installation – factory set
at approximately 38°C) with full anti-scald
protection throughout the range.
Should there be a loss of ow to either incoming
supply then water from the shower will stop or
be reduced until both supplies are restored.
Recommended Outlet Temperatures
The BuildCert TMV scheme recommends a
maximum mixed water outlet temperatures of
41°C for showers.
The mixed water temperatures must never
exceed 46°C.
The British Burns Association recommends 37°C
to 37.5°C as a comfortable bathing temperature
for children.
Adjusting the Maximum Temperature
Override Setting
Remove the temperature control by removing
the end cap then unscrewing the retaining screw
(g.12).
Remove the plastic adaptor from the
temperature spindle then turn the flow
control to full flow. With a steady flow
running, adjust the temperature valve spindle
until the temperature is about 38°C.
When you are satised with the temperature turn
the ow control off. Ret the plastic adaptor and
temperature control, secure with the screw and
replace the end cap.