2181655A - March 2022
OMNICARE
SR pumped shower
INSTALLATION AND OPERATING INSTRUCTIONS
Please read this book thoroughly and familiarise yourself with all instructions before commencing
installation and keep it for future reference.
The shower installation MUST be carried out by a suitably qualified person, in the sequence of
this instruction book.
IMPORTANT SAFETY ADVICE
The shower unit MUST BE switched off at the
isolating switch when not in use. This is a
safety procedure recommended for all
electrical appliances.
The shower head and hose supplied with this
product are a safety critical part of your shower.
Failure to use genuine Triton parts may cause
injury and invalidate your guarantee.
FOR YOUR SERVICE REFERENCE
NOTE DOWN THE PRODUCT CODE BELOW
(FROM THE FRONT OR TOP OF THE BOX)
ALTERNATIVELY REGISTER BY TEL: 024 7637 8321
THIS OFFER IS NOT VALID OUTSIDE THE UK
REGISTER ONLINE
ENTER A PRIZE DRAW
WIN
£100
LOVE2SHOP VOUCHERS
VISIT OUR WEBSITE TODAY
TRITONSHOWERS.CO.UK/REGISTER
PRODUCT REGISTRATION IS ONLY AVAILABLE
TO UNITS PURCHASED & INSTALLED IN THE UK
! IMPORTANT !
Under *NO circumstances must this shower be connected directly
to a mains water supply. It is designed for GRAVITY FED
COLD WATER systems ONLY !
*Failure to comply may invalidate product warranty

Other manuals for Triton Omnicare

Questions and Answers

  • C
    Charlene MosleyAug 18, 2025
    What to do if my Triton Bathroom Fixture shower is inoperable?
    • D
      David GalvanAug 18, 2025
      If your Triton Bathroom Fixture shower is inoperable with no water flow, first, check the power supply by renewing or resetting the fuse or circuit breaker. If the issue persists, consult a qualified electrician. Also, unit malfunction can be a cause, so you should check other appliances. If the thermal cut-out or the PCB-NTC has operated, have the unit checked by a suitably qualified service engineer or contact Customer Experience.
  • R
    Randall GonzalezAug 20, 2025
    How to fix a Triton Bathroom Fixture shower with no water flow?
    • R
      Ryan VelezAug 20, 2025
      If your Triton Bathroom Fixture shower isn't working and no water is flowing, first check the power supply by renewing or resetting the fuse or circuit breaker. If the issue continues, it may be a unit malfunction, so check other appliances or contact your local Electricity Supply Co. If the thermal cut-out has operated, have the unit checked by a qualified service engineer or contact Customer Experience. If the reason is not mentioned, have the unit checked and contact Customer Experience.
  • M
    Melinda ChandlerAug 23, 2025
    Why is the water too hot in my Triton Bathroom Fixture?
    • J
      Jessica ThompsonAug 23, 2025
      If the water from your Triton Bathroom Fixture is too hot, try adjusting the temperature control. If that doesn't solve the issue, have the unit checked by a qualified service engineer or contact Customer Experience.
  • J
    John BakerAug 26, 2025
    Why does the low flow LED come on and the shower switch off on my Triton Bathroom Fixture?
    • K
      Kathryn OliverAug 26, 2025
      If the low flow LED comes on when the shower is running and the shower switches off, it means a low flow condition has caused the temperature sensor in your Triton Bathroom Fixture shower to operate. The shower won't restart until the water cools and the LED goes off. If the problem persists, check that the shower head isn't blocked, the shower hose isn't restricted, the filter isn't blocked, and the water supply to the shower is adequate.
  • T
    Travis RothAug 28, 2025
    Why is the water too cold in my Triton Bathroom Fixture?
    • J
      Joseph EdwardsAug 28, 2025
      If the water from your Triton Bathroom Fixture is too cool or cold, start by adjusting the temperature control. If that doesn't work, adjust the maximum temperature stop. If the issue persists, have the unit checked by a qualified service engineer or contact Customer Experience.
  • A
    Adam KentAug 30, 2025
    How to stop continuous water flow in a Triton Bathroom Fixture?
    • G
      Gloria MitchellAug 31, 2025
      If water won't stop flowing from your Triton Bathroom Fixture unless you switch it off at the isolating switch, the control ribbon cable might not be connected to the PCB. Remove the cover and connect the ribbon cable.
  • B
    Bernard Lyons PhDSep 2, 2025
    What to do if water is ejected from the PRD tube of my Triton Bathroom Fixture?
    • M
      moodyrichardSep 2, 2025
      If the pressure relief device on your Triton Bathroom Fixture has activated, causing water to eject from the PRD tube, it could be due to a blocked shower head. Clean the spray plate and fit a new PRD. Alternatively, the flexible shower hose might be twisted or blocked; check for free passage through the hose, replace it if necessary, and then fit a new PRD. It could also be that the shower head was not removed during commissioning, so fit a new PRD and commission the unit with the shower head removed.
  • J
    Julie OwenSep 4, 2025
    What does it mean when the low flow LED flashes on my Triton Bathroom Fixture?
    • T
      Timothy VelazquezSep 4, 2025
      If the low flow LED flashes continuously when you press the start/stop button and the shower won't start on your Triton Bathroom Fixture, it indicates that the pressure switch has failed. Replace the pressure flow switch assembly.
  • H
    Hannah JosephSep 7, 2025
    Why are the low flow and shutdown LEDs flashing alternately on my Triton Bathroom Fixture?
    • J
      Jerry CurtisSep 7, 2025
      If the low flow and shutdown LEDs are alternately flashing when you turn on the power to your Triton Bathroom Fixture and the shower won't start, it means the start/stop switch has failed. Replace the cover assembly.
  • B
    Brandon BrownSep 9, 2025
    What to do if low flow and shutdown LEDs flash simultaneously on my Triton Bathroom Fixture?
    • D
      Diana PerrySep 9, 2025
      If the low flow and shutdown LEDs are flashing simultaneously when you press the start/stop button and the shower won't start on your Triton Bathroom Fixture, it indicates that the outlet thermistor has failed. Replace the thermistor.

Summary

Safety First

Important Safety Information

Essential safety warnings and operating precautions for the shower unit.

Introduction and Safety

General Guidance Notes

Plumbing Requirements

Compliance with regulations, pipe flushing, and connection standards for plumbing.

Electrical Requirements

Compliance with wiring regulations, earthing, RCD, and circuit protection standards.

Product Specifications

Installation Procedure

Plumbing and Positioning

Plumbing requirements and guidance on correct shower unit placement.

Electrical Installation

Detailed electrical requirements, cable sizing, and circuit protection.

Step-by-Step Installation Process

Detailed steps from positioning to commissioning the shower unit.

BEAB Care Setting

Procedure for setting the shower to meet BEAB Care mark specifications (41°C maximum).

Operating Instructions

Maintenance and Testing

Troubleshooting Guide

Common Faults and Solutions

Categorised list of common problems and their corresponding actions/solutions.

Commissioning and Testing Notes

UK Service Policy and Guarantee

Triton UK Standard Guarantee

Terms and conditions of the manufacturer's guarantee for the shower unit.

Triton Omnicare Specifications

General IconGeneral
TypeElectric Shower
Temperature ControlThermostatic
Water Connection15mm compression
Start/Stop ButtonYes
MaterialPlastic
FinishWhite
Installation TypeWall Mounted
Warranty2 years
Water Entry PointsBottom
Cable Entry PointsBottom Entry
ApprovalsWRAS