Bar Mixer Shower
4
INTRODUCTION
This book contains all the necessary tting and
operating instructions for your mixer shower.
Please read them carefully and read through
the whole of this book before beginning your
installation.
The shower installation must be carried out by
a suitably competent person and in sequence of
this instruction book.
Care taken during the installation will give a long
and trouble free life from your mixer shower.
SITE REQUIREMENTS
The installation must be in accordance with
water supply (water ttings) regulation 1999
and/or local Bylaws.
Maximum static
pressure (Bar)
10
Flow pressure, Hot
&Cold (Bar)
0.5 to 5
Hot supply
temperature (°C)
55 to 65
Cold supply
temperature ( °C)
Equal to or less than 25
This mixer shower is designed for high pressure
systems found in the UK, but can be installed
with low pressure gravity water systems with
reduced ow rates.
For effective operation of the internal seals, the
maximum static pressure must not be exceeded.
A stored water temperature of 60°C is
considered sufcient to meet all normal
requirements and will minimise the effects of
scale in hard water areas.
Pressure Reducing Valve
On sites where the running pressure is above 5
bar, the use of a suitably sized pressure reducing
valve tted in the cold mains supply pipework
can provide nominally equal pressures at the
mixer shower.
Water Minimum Flow Rate
For best performance within the specied running
pressure range a minimum ow of 8 litres per
minute should be available to both inlets.
SAFETY WARNINGS
DO NOT choose a position where the mixer
shower could become frozen.
DO NOT connect this mixer shower to any
form of tap or fitting not recommended by the
manufacturer.
DO NOT allow the inlet pressure or ow rates
to operate outside the guidelines laid out in Site
Requirements.
DO NOT connect the mixer shower to a gravity
hot supply and a mains cold supply or vice versa.
APPROVALS
This mixer valve has the following approvals:
• WRAS
• TMV2 (BS EN 1111)
Designation: HP-S (high pressure shower
only)
On pressures above 0.5 bar.