The following can be carried out by a competent person
FAULT FINDING
1 Water too hot. 1.1 Temperature
control incorrectly
commissioned.
1.1.1 Refer to the Commissioning section.
1.2 Not enough cold
water flowing
through shower.
1.2.1 Reposition the temperature control knob.
1.3 Increase in the
ambient cold water
temperature.
1.3.1 Reposition the temperature control knob.
1.4 Cold water supply
blocked.
1.4.1 Turn off the shower and consult a competent
plumber or contact Customer Experience.
1.5 High volume of cold
water drawn off
elsewhere.
1.5.1 Reduce the simultaneous demand from
the supply.
2 Water too cold. 2.1 Temperature control
incorrectly
commissioned.
2.1.1 Refer to the Commissioning section.
2.2 Not enough hot
water flowing
through shower.
2.2.1 Reposition the temperature control knob.
2.3 Decrease in the
ambient cold water
temperature.
2.3.1 Reposition the temperature control knob.
2.4 Decrease in the
ambient cold water
temperature.
2.4.1 Make sure the heating appliance is set to
maximum or has sufficient stored hot water.
2.4.2 Make sure the heating appliance is igniting by
trying a hot water tap elsewhere.
2.5 Hot water supply
blocked or restricted.
2.5.1 Turn off the shower and consult a competent
plumber or contact Customer Experience.