Troubleshooting guide
Fault Cause Remedy
After switching on
no LED lights up.
No operating voltage.
Device fuse or vehicle fuse
defective.
Check 12 V / 24 V battery voltage,
charge battery if necessary.
Check all electrical plug connections.
Check fuse of device or vehicle and replace if necessary
(see fuses)
After switching on the
greenLED lights up,but the
heater is not running.
The temperature setting on
the control panel is lower
than the room temperature
Select higher room temperature at the control panel.
Red LED flashes 1x per sec.
Red LED flashes 3x per sec.
Open window above cowl
(window switch).
Undervoltage range
12 V: 10.9 V – 10.5 V,
24 V: 21.8 V – 20.7 V.
Overvoltage range
12 V: 15.8 V – 16.4 V,
24 V: 31.8 V – 33.1 V.
Close window.
Charge battery.
Check battery voltage and voltage sources such as the
charger.
Approx. 30 sec. after the
heater is switched on, the
red LED comes on.
Valves in gas supply line
closed.
Combustion air intake or
exhaust outlet is sealed.
Check gas supply and open valves.
Remove the cowl cover.
Inspect openings for contamination (slush, ice, leaves, etc.)
and remove contamination if necessary.
After operating for a longer
period of time, the heater
switches to failure.
Warm air outlets blocked.
Circulated air intake
blocked.
Inspect individual outlet openings.
Remove blockage from circulated air intake.
If these actions do not remedy the problem, please contact Truma Service.