30
calibrate gap or black mark sensor, depends on the sensor setting in the last print
job.
Please follow the steps below to calibrate the sensor.
1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes amber and blinking. (Any amber will do
during the 5 blinks).
The LED color will be changed as following order.
Amber Æ red (5 blinks) Æ amber (5 blinks) Æ green (5 blinks) Æ
green/amber (5 blinks) Æ red/amber (5 blinks) Æ solid green
4. It calibrates the sensor and measures the label length and prints internal settings
then enter the dump mode.
Note:
Please select gap or black mark sensor by Diagnostic tool or by GAP or
BLINE command prior to calibrate the sensor.
For more information about GAP and BLINE command, please refer to TSPL2