Getting Started
Turning On/Off and Basic Operation
4
Turning On/Off and Basic Operation
To quickly get you started with the QUESTempº 34 & 36 model, the following section explains
how to turn on the instrument, run, and stop your session.
1. Press the I/O Enter key to turn on. Following the model and revision information displayed
on the screen, the main menu will appear.
VIEW PRINT
SETUP RESET
Indicator arrow
Indicates the selected menu option. Then press I/O
enter to select or press up/down arrows to select
another option
Figure 1-3: Main menu of the QUESTempº 34 & 36
2. Press the I/O Enter key (when view is selected) to access the measurement screens.
The Wet and Dry measurements screen will display. (See Figure 1-6 for screen
example.)
3. To view different measurements, press the Up or Down arrow key to toggle through the
views.
NOTE: There are five user-selectable languages. If you see the fields such as Wet, Dry,
WBGTi, and WBGTo this indicates the measurements are displaying in English.
To display an alternative language, select Setup from the main menu. Press the Down
arrow repeatedly until “English” (or the appropriate language) appears. Then repeatedly
press the I/O enter key to toggle through the languages. Once selected, all menus and
measurement screens will change to the selected language. To return to the main
menu, press the Run/Stop key.
4. To return to the main menu, press and hold the I/O Enter key (3, 2, 1 countdown will
appear) and the main menu will display.
To select an option on the main menu, press the up or down arrow until an arrow
appears directly in front of the appropriate menu selection and then press I/O enter key.
5. To power off, press and hold the I/O enter key from the main menu.
Placement for Monitoring/Testing
The QUESTempº 34 & 36 model should be placed at a height of 3.5 feet (1.1 m) for standing
individuals or 2 feet (.6 m) for seated individuals. Tripod mounting is recommended to get the unit
away from anything that might block radiant heat or air flow. A 1/4" x 20 threaded bushing on the
bottom of the instrument allows mounting to a standard photographic tripod. DO NOT stand close to
the unit during sampling.
NOTE: Before measuring, allow 10 minutes for the sensors readings to stabilize.