16
TMRP
The TMRP is a compact switch button unit that is dedicated to display status and control of the
redundant system.
Mounting
The unit is supplied with a 1RU mounting bracket and two blanking plates. The TMRP can be mounted in
any one of three positions.
Power
The TMRP has both a DC power input for use with the supplied 12Vdc PSU and PoE (Power over Ethernet)
to receive power from a PoE enabled ethernet switch. Either power method can be used, or both can be
used in conjunction to provide resilient power for the unit.
Connections
The TMRP has several connections available. Power (either 12Vdc or PoE) and ethernet are required to
be able to operate with the TallyMan Redundancy system however, in addition, there is GPO available
that can be used to trigger external changeover units or feed status into a monitoring system.
Button
Restores factory settings – Resets IP address and password of unit
100Base-T Full Duplex, PoE Class 3, 12 Watt