EasyManua.ls Logo

TurboChef 2020

TurboChef 2020
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 TROUBLESHOOTING
NO
YES
YES
NO
R
emove the
obstr
uction.
Troubleshoot F1
fault (pages
27-28).
R
eplace the
defectiv
e
heater(s).
T
est the RTD
(page 22 for r
esistance/
temperature chart).
I
s the R
TD damaged
or defectiv
e (page 22)?
NO
Replace the I/O control
boar
d (page A-8).
YES
YES
Troubleshooting:
F5: C
C OVER TEMP
I
s anything obstr
ucting
r
egular air
flow into the
cook chamber?
Is an F1 fault
pr
esent?
YES
NO
P
lace the o
v
en in
TEST
MODE and test the heaters
(page 17). Do measure-
ments show the heaters are
ok (page 24)?
I
s the solid state
r
elay functioning
properly?
NO
R
eplace the SSR (page
A-7).

Table of Contents

Other manuals for TurboChef 2020