THE CONTROL S
YSTEM
ISSUE RESOLUTION
F2: Cook Temperature
Low
1. Verify the High-Limit Thermostat is not tripped.
o
If High-Limit is tripped: Reset and allow the oven to warm-up.
o
If High-Limit is not tripped: Follow the instructions below.
High-Limit is not tripped.
Place a small water load in a microwave transparent container (approx.
275 ml) in the oven and place the oven in Test Mode. Press the
“MGTRON” Key to actuate the microwave. While holding down the
“MGTRON” Key watch the CC and IR Temperatures. If either tem-
perature bounces substantially there may be a noise (EMI) problem. To
correct this problem examine the wire routing for each Thermocouple
wire. If the wires are routed near any high voltage components such as
the Magnetron or High Voltage Transformers re-route the wires. If this
does not correct the problem, verify that both Magnetrons are securely
mounted. Call Customer Service for further details at
800.90TURBO.
20