EasyManuals Logo

turck PS Series Instruction Manual

turck PS Series
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
5
more@turck.com • www.turck.com • 2012/01
Pressure Sensors Series PS…
Pressure Sensors Series PS
4 Installation and setup instructions
Even though the device is excellently protected against electro-magnetic
interference, installation and cabling must be carried out correctly to
ensure interference immunity.
Never route signal and control cables together with the trunk line or feeder
cables of motors, cylinder coils, rectifiers etc. The cables must be routed in
conductive and grounded cable conduits. This applies especially to long-
distance cables, or environments in which the cables are exposed to strong
radio waves from broadcasting stations.
Signal lines should be installed in mounting cabinets and as far away as
possible from contactors, control relays, transformers and other sources of
interference.
The housing surface may not be painted or coated, because the reference
port could be clogged.
5 Mounting
Prior to mounting or removing the sensor it must be verified that the
system is depressurized.
Do not mount sensors in locations subject to high pressure pulses.
Significant thermal changes in the sensor environment can lead to a
zero shift. As a result, the measuring value displayed in a depressurized
state will read zero. This kind of drift can be corrected see chapter 11.2,
parameter CoF).
The read direction of the on-site display can be rotated via software by
180° (see chapter 11.2, parameter diS).

Table of Contents

Other manuals for turck PS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the turck PS Series and is the answer not in the manual?

turck PS Series Specifications

General IconGeneral
Brandturck
ModelPS Series
CategoryAccessories
LanguageEnglish

Related product manuals