Hans Turck GmbH & Co. KG • Tel. +49 (0) 208/4952-0 • Fax +49 (0) 208/4952-264
8
Pressure Sensors Series PS…
8 Programming of parameter values
Press the MODE button. The display shows the parameter ”Uni”. (If
„Loc” is displayed , the sensor must be unlocked first. For this, please
see paragraph 8.2 further down. Once unlocked, you can now view
the setting of the parameter ”Uni” (see below) or select other para-
meters. To select other parameters, press the MODE button several
times.
To view a certain parameter value, just press the SET button briefly.
To alter this value, press and hold the SET button for 5 s until the
value stops flashing. Arrow upwards or downwards to change the
value.
Press the recessed ENTER button to save the changes.
The new setting is activated.
8.1 Locking/Unlocking (disabling/enabling)
The access to the menu and to the programming mode can be lo-
cked and unlocked.
To lock, call up the RUN mode, press and hold both the MODE and
SET button until „Loc“ appears on the display.
To unlock, call up the RUN mode, press and hold both the MODE and
SET button again until „uLoc“ appears on the display.