11.2 Parameters sub-menu (EF)
Parameter Explanation Options Function
Hi Max. value memory The max. value is memorized and
displayed/deleted here
Lo Min. value memory The min. value is memorized and
displayed/deleted here
CoF Offset correction Significant thermal changes in
the sensor environment can
lead to zero shift. As a result, the
measuring value displayed in a
depressurized state will not read
zero. This drift can be corrected.
Adjustment range: -5 to +5 % of the
measuring span
dSP1 Switching delay of SP1
Only type:
PS…LI2UPN…
PS…2UPN…
Adjustable range: 0 … 50 s in
increments of 0.1 s (0 = delay time
is not active)
drP1 Switching delay of rP1
Only type:
PS…LI2UPN…
PS…2UPN…
Adjustable range: 0 … 50 s in
increments of 0.1 s (0 = delay time
is not active)
dFH1 Switching delay of FH1 Adjustable range: 0 … 50 s in
increments of 0.1 s (0 = delay time
is not active)
dFL1 Switching delay of FL1 Adjustable range: 0 … 50 s in
increments of 0.1 s (0 = delay time
is not active)
dSP2 Switching delay of SP2
Only type:
PS…LI2UPN…
PS…2UPN…
Adjustable range: 0 … 50 s in
increments of 0.1 s (0 = delay time
is not active)
drP2 Switching delay of rP2
Only type:
PS…LI2UPN…
PS…2UPN…
Adjustable range: 0 … 50 s in
increments of 0.1 s (0 = delay time
is not active)
dFH2 Switching delay of FH2
Only type:
PS…LI2UPN…
PS…2UPN…
Adjustable range: 0 … 50 s in
increments of 0.1 s (0 = delay time
is not active)