21
more@turck.com • www.turck.com • 2012/01
Pressure Sensors Series PS…
Pressure Sensors Series PS
14 Technical data
Type PS 300 PS 500 PS 600
Pressure range -1…600 bar -1…600 bar -1…400 bar
Type of pressure Relative/absolute
Outputs Transistor switching output, analog output
and IO-Link (freely konfigurable)
IO-Link COM2 38.4 kBaud Frame Type 2.2
Current output (0) 4…20 mA
Voltage output 0…10 V, 0…5 V, 1…6 V
Deviation from typ. curve
(NLHR), Non-linearity, hystere-
sis und repeat accuracy
± 0.5 % of span
Output function 2 PNP/NPN, N.C. / N.O., progr.
Switchpoint accuracy ± 0.5 % v. span
Switchpoint clearance
0.5 % v. span
Switchpoints (min + 0.005 x span) … 100 % v. span
Release positions min … (SP -0.005 x span)
Switching frequency
180 Hz
Operating voltage 15…30 VDC with
2 switching outputs
18…30 VDC with analog output
SELV, PELV to EN 50178
No-load current I
0
50 mA
Medium temperature -40…85 °C on request
Ambient temperature -40…80 °C
Storage temperature -40…80 °C
T
K
:
– zero point/10K
– span per/10K
± 0.15 %
± 0.15 %
Voltage drop at I
e
2 V

Table of Contents

Other manuals for turck PS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the turck PS Series and is the answer not in the manual?

turck PS Series Specifications

General IconGeneral
Brandturck
ModelPS Series
CategoryAccessories
LanguageEnglish

Related product manuals