Hans Turck GmbH & Co. KG • Tel. +49 (0) 208/4952-0 • Fax +49 (0) 208/4952-264
20
Pressure Sensors Series PS…
Delivery of the PS Series (Continuation)
Parameter Explanation further information
drP2 0.0 available with 2UPN8X and LI2UPN8X
not available with LUUPN8X
dFH2 0.0 only with window function Fno or Fnc
available with 2UPN8X and LI2UPN8X
dFL2 0.0 not available with LUUPN8X
only with window function Fno or Fnc
dAP 0.00 available with 2UPN8X and LI2UPN8X
not available with LUUPN8X
dAA 0.00 available with LI2UPN8X and LUUPN8X
not available with 2UPN8X
P-n PnP
diS 50
rES Reset to standard factory setting
SOF ≥ 1.0.1.0
Value table
Type Start
point
Ende
point
Switch
point
Release
point
Analog range
initial value
Analog range
end value
01VR -1 0 -0.5 -0.75 -1 0
001R 0 1 -0.5 0.25 0 1
001V -1 1 -0.5 0.25 0 1
003V -1 2.5 1.25 0.625 0 2.5
010V -1 10 5 2.5 0 10
016V -1 16 8 4 0 16
025V -1 25 12.5 6.25 0 25
040V -1 40 20 10 0 40
100R 0 100 50 25 0 100
250R 0 250 125 62.5 0 250
400R 0 400 200 100 0 400
600R 0 600 300 150 0 600
001A 0 1 0.5 0.25 0 1
003A 0 2.5 1.25 0.625 0 2.5
010A 0 10 5 2.5 0 10
016A 0 16 8 4 0 16
025A 0 25 12.5 6.25 0 25