EasyManua.ls Logo

Tuttnauer 2540EA - Service Manual

Tuttnauer 2540EA
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OPERATION
&
MAINTENANCE
MANUAL
Electronic Tabletop Autoclaves
Models 1730, 2340, 2540, 3140, 3850, 3870
E, EK, EA & EKA

Other manuals for Tuttnauer 2540EA

Questions and Answers

Summary

General Autoclave Information

Incoming Inspection Procedure

Inspect the autoclave for damage upon arrival and verify packing integrity.

Technical Data and Specifications

Electrical Data and Fuse Ratings

Provides detailed electrical specifications, including voltage, amperage, and fuse ratings.

Physical Specifications and Dimensions

Presents overall dimensions, weight, and other physical characteristics of the autoclave models.

Detailed Technical Specifications

Lists chamber dimensions, water reservoir capacity, tray sizes, and shipping details.

Keyboard and Display Interface

Control Panel Keyboard Functions

Detailed explanation of program keys and other control buttons on the autoclave interface.

Displayed Messages and Safety Measures

Explains common messages, error codes, and safety measures displayed by the autoclave.

Sterilization Programs Guide

Program 1: Unwrapped Instruments

Details the settings and sequence for sterilizing unwrapped instruments.

Program 2: Wrapped Instruments and Porous Loads

Outlines the parameters for sterilizing wrapped instruments and porous materials.

Program 3: Glassware Sterilization

Specifies the cycle for sterilizing glassware with slow exhaust and no drying.

Program 4: Accessory (Dry Only)

Describes the program used for an additional drying cycle for specific items.

Installation and Setup Instructions

Electrical Connection Requirements

Guides on proper electrical connection, safety, and compliance with regulations.

Automatic Water Filling System Setup

Procedures for setting and checking the automatic water filling system.

Preparation Before Sterilization

Operating the Autoclave

Maintenance Procedures

Preventive and Scheduled Maintenance

Covers daily, weekly, and periodic maintenance tasks for optimal device performance.

Troubleshooting for the Operator

Tuttnauer 2540EA Specifications

General IconGeneral
TypeAutomatic Autoclave
Voltage120V or 230V
Frequency50/60 Hz
Power1400W
Door TypeManual
Number of Trays2
Safety Featuresautomatic shut off at the end of both sterilization and drying cycles, Overheat cut-off, automatic shut off at the end of both sterilization and drying cycles, insufficient water level sensor

Related product manuals