l Connect the test leads to the proper terminals as said above to avoid error display.
The LCD will display “1 indicating open-circuit for wrong connection. The unit
of diode is Volt (V), displaying the positive-connection voltage-drop value.
l When diode testing has been completed, disconnect the connection between
the testing leads and the circuit under test.
Measurement Operation (12)
The Model UT33C/UT33D: Testing for Continuity
To test for continuity, connect the Meter as below:
1. Insert the red test lead into the VmA terminal and the black test lead into the
COM terminal.
2. Set the rotary switch to .
3. Connect the test leads across with the object being measured.
The buzzer sounds if the resistance of a circuit under test is less than 70Ω.
Note
l The LCD displays “1” indicating the circuit being tested is open.
24
Model UT33B/C/D: OPERATING MANUAL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT33C and is the answer not in the manual?

UNI-T UT33C Specifications

General IconGeneral
DC Current Range200μA/2000μA/20mA/200mA/10A
Diode TestYes
Continuity BuzzerYes
Battery9V (6F22)
Weight156g
DC Voltage Range200mV/20V/200V
AC Voltage Range200V
Resistance Range200Ω/2kΩ/20kΩ/200kΩ/20MΩ
Display1999
Capacitance RangeNot available
Frequency RangeNot available