2. Turn the Meter to OFF position.
3. Remove the screw from case bottom, and separate the case bottom from the
case top.
4. Remove the battery from the battery compartment.
5. Replace the battery with a new 9V battery (NEDA 1604 or 6F22 or 006P).
6. Rejoin the case bottom and case top, and reinstall the screw.
C. Replacing the Fuses (See figure 8)
Maintenance(3)
To avoid electrical shock or arc blast, or personal injury or damage to the
Meter, use specified fuses ONLY in accordance with the following procedure.
Warning
To replace the Meter’s fuse:
1. Disconnect the connection between the testing leads and the circuit under test,
and remove the testing leads away from the input terminals of the Meter.
2. Turn the Meter to OFF position.
39
Model UT33B/C/D: OPERATING MANUAL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT33C and is the answer not in the manual?

UNI-T UT33C Specifications

General IconGeneral
DC Current Range200μA/2000μA/20mA/200mA/10A
Diode TestYes
Continuity BuzzerYes
Battery9V (6F22)
Weight156g
DC Voltage Range200mV/20V/200V
AC Voltage Range200V
Resistance Range200Ω/2kΩ/20kΩ/200kΩ/20MΩ
Display1999
Capacitance RangeNot available
Frequency RangeNot available