EasyManuals Logo

UNI-T UT33C User Manual

UNI-T UT33C
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Measurement Operation (15)
G. The Model UT33B: Battery Test (see figure 7)
To avoid harms to you or damages to the Meter,
please do not attempt to input voltages higher
than 60V in DC or 30V in AC.
Warning
( figure 7)
To test the battery, proceed as follows:
1. Insert the red test into the VmA terminal and
the black test leads into the COM terminal.
2. Set the rotary switch to an appropriate
measurement position in range.
3. Connect the test leads across with the battery
being measured ensuring the polarity is correct.
The measured value shows on the display, which
is the voltage between the cathode and anode of
the battery.
27
Model UT33B/C/D: OPERATING MANUAL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT33C and is the answer not in the manual?

UNI-T UT33C Specifications

General IconGeneral
DC Current Range200μA/2000μA/20mA/200mA/10A
Diode TestYes
Continuity BuzzerYes
Battery9V (6F22)
Weight156g
DC Voltage Range200mV/20V/200V
AC Voltage Range200V
Resistance Range200Ω/2kΩ/20kΩ/200kΩ/20MΩ
Display1999
Capacitance RangeNot available
Frequency RangeNot available