2. Set the rotary switch to
o
C
or
o
F
.
3. Place the temperature probe to the object being measured.
The measured value shows on the display.
Note
l The Meter automatically displays the temperature value inside the Meter when
there is no temperature probe connection.
l The included point contact temperature probe can only be used up to 250
o
C(482
o
F).
For any measurement higher than that, the rod type temperature probe must
be used instead.
l When temperature measurement has been completed, disconnect the connection
between the testing leads and the circuit under test.
Measurement Operation (14)
26
Model UT33B/C/D: OPERATING MANUAL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT33C and is the answer not in the manual?

UNI-T UT33C Specifications

General IconGeneral
DC Current Range200μA/2000μA/20mA/200mA/10A
Diode TestYes
Continuity BuzzerYes
Battery9V (6F22)
Weight156g
DC Voltage Range200mV/20V/200V
AC Voltage Range200V
Resistance Range200Ω/2kΩ/20kΩ/200kΩ/20MΩ
Display1999
Capacitance RangeNot available
Frequency RangeNot available