10. Specification
This chapter includes the contens as follows.
Technical Index
Model and Function
Environmental Requirement
10.1 Technical Index
Note: Guarantee period of precision is one year.
Model
UT5310A+
UT5310D+
UT5310R+
UT5320R+/S4A/S8A
Withstand Voltage Test
Output
Voltage
AC
Voltage
Rnge
0.050kV5.000kV
0.050kV5.000kV
Voltage
Wave
Sine wave
Sine wave
Distortion
< 3
< 3
Operating
Frequency
50, 60Hz (optional)
50, 60Hz (optional)
Accuracy of
Frequency
±1%
±1%
Output
Power
50VA5.000kV 10mA
100VA 5.000kV
20mA
Regulated
rate of
Voltage
±(1.0%+50V)(rated power
±(1.0%+50V) (rated
power
DC
Voltage
range
0.050 kV6.000kV
0.050 kV6.000kV
Frequency
of Signal
Source
600Hz
600Hz
Output
Power
30VA6.000kV 5mA
60VA6.000kV 10mA
Regulated
rate of
Voltage
±1.0% +100V) (rated power
±1.0% +100V) (rated
power
AC/DC
Rsoulation
of Voltage
1V