109
UTD4000 Four-channel
User Manual
Vertical
Model
UTD4304C
A/D converter
8-bit resolution
Deflection graticule factor V/div Range
2mV/div ~ 5V/div at input BNC
Displacement range
±
div
5
Analog bandwidth
Low frequency response (AC coupling, -3dB)
UTD4204C
UTD4104C
300MHz
200MHz
100MHz
Single bandwidth
100MHz
100MHz
100MHz
Selectable analog bandwidth limit (Typical)
20MHz
10Hz at BNC
Rise time
1.2ns
1.8ns
3.5ns
DC gain accuracy
When vertical sensitivity is 2mV/div : 4% (sampling or average acquisition mode)
When vertical sensitivity is 5mV/div~5V/div : 3% (sampling or average acquisition mode)
±
±
DC measurement accuracy
(average acquisition mode)
When vertical position is zero and N 16 :
(5% x reading 0.1 div 1mV) and 2mV/div is selected
(3% x reading 0.1 div 1mV) and 5mV/div~5V/div is selected
When vertical position is not zero and N 16 :
3% x (reading vertical shift reading) (1% x vertical shift reading)
0.2div). Set from 5mV/div to 200mV/div plus 2mV
Setup value > 200mV/div to 5V/div plus 50mV
± + +
± + +
± [ + + ] +
Voltage difference ( V)
measurement accuracy
(average acquisition mode)
Under identical setup and environmental conditions, the voltage difference
( V) between two points of the waveform after the average of 16 waveforms
acquired waveforms is taken : (3% x reading 0.05div)
± +