Easier to Read BCD396T/UBCD396T Digital Scanner Manual
Quickly Storing a Conventional Frequency
To program a frequency into a 'Quick Save Group' in a 'Quick Save System', in scan mode press Hold to hold on any channel.
Enter the frequency and press E/yes.
At 'Quick Freq Save?' press E/yes.
Note: If the frequency is already stored in the group, 'Frequency Exists Accept? (Y/N)' appears. Press (.)no to return.
The scanner will save the frequency in a (created) group called 'Qck Save Grp' in a (created) system called 'Qck Save Cnv Sys' (with no quick keys
assigned) and you will be at the '
Edit Channel' menu to complete the settings for the new channel. If you don't want to edit the channel settings or are done editing
the channel, press L/O to return to 'Hold' to enter another frequency or Scan to exit.
Then see
Edit Channel Options, Edit Group Options, and Edit Systems Options to customize the channel(s), group, and system.
To program a frequency into an existing group, Hold on any channel.
Enter the frequency and press E/yes.
At 'Quick Freq Save?' press (.)no.
At 'Select System' scroll to the system where you want to store the frequency and press E/yes.
At 'Select Group' scroll to the group where you want to store the frequency and press E/yes.
Note: If the frequency is already stored in the group, 'Frequency Exists' Accept? (Y/N)' appears. Press (.)no to return.
After storing the frequency, you will be at the '
Edit Channel' menu to complete the settings for the new channel. If you don't want to edit the channel settings or are
done editing the channel, press L/O to return to 'Hold' to enter another frequency or Scan to exit.
Contents
Quickly Storing an ID Note: You have to program the trunking system first. See Programming Trunking Systems.
To program a ID into a 'Quick Save Group', Hold on any channel in the system you want to store the ID in.
.
Enter the ID (see
Entering IDs) and press E/yes.
At 'Quick TGID Save?' press E/yes.
At 'Select System' scroll to the system where you want to store the ID and press E/yes.
Note: If the ID is already stored in the group, 'TGID Exists Accept? (Y/N)' appears. Press (.)no to return.
The scanner stores the ID into a (created) channel group called 'Qck Save Grp' (with no quick key assigned) and you will be at the '
Edit Channel' menu to
complete the settings for the new channel. If you don't want to edit the channel settings or are done editing the channel, press L/O to return to 'Hold' to enter
another frequency or Scan to exit.
Then see
Edit Channel Options and Edit Group Options to customize the channel(s), and group.
To program a ID into an existing group, Hold on any channel.
.
Enter the ID (see
Entering IDs) and press E/yes.
At 'Quick TGID Save?' press (.)no.
At the 'Select System' scroll to the system where you want to store the ID and press E/yes.
Scroll to the group where you want to store the ID and press E/yes.
Note: If the ID is already stored in the group, 'TGID Exists Accept? (Y/N)' appears. Press (.)no to return.
After storing the ID, you will be at the '
Edit Channel' menu to complete the settings for the new channel. If you don't want to edit the channel settings or are done
editing the channel, press L/O to return to 'Hold' to enter another frequency or Scan to exit.
Manually Programming Channel Frequencies/TGIDs
Contents
http://marksscanners.com/396/396.shtml (24 of 51)8/17/2010 10:11:40 PM

Other manuals for Uniden BCD396T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uniden BCD396T and is the answer not in the manual?

Uniden BCD396T Specifications

General IconGeneral
BrandUniden
ModelBCD396T
CategoryRadio
LanguageEnglish

Related product manuals