Easier to Read BCD396T/UBCD396T Digital Scanner Manual
SS: The state code.
CCC: The county code.
Scroll to 'Program SAME' and press E/yes.
At 'Select SAME' scroll to the SAME group (1-5) and press E/yes.
At 'Edit Name' see
Entering Text to edit the name otherwise scroll to 'Edit County' and press E/yes.
At 'Select Code No' scroll to the spot for the code# (1-8) and press E/yes.
At 'Edit FIPS Code' enter the FIPS code and press E/yes to save and exit.
Scroll to the next spot for the next code and repeat
Press Menu twice to return and select a different SAME group.
Press Menu to save and exit.
Contents
Set Delay Time Sets the number of seconds the scanner should wait after a transmission stops before moving on to the next channel during weather scan. The default
setting is 2 seconds.
Scroll to 'Set Delay Time' and press E/yes.
Scroll to 1, 2, 3, 4, 5, (seconds) or Off and press E/yes to save and exit.
Set Attenuator Sets the attenuator (18 dB) for weather operation. The default setting is off.
Scroll to 'Set Attenuator' and press E/yes.
Scroll to On or Off and press E/yes to save and exit.
Weather Alert This setting turns on weather alert and determines which types of signals will trigger an alert. The scanner will mute and scan only the weather channels.
Warning! If you receive an alert it will be at FULL volume.
Scroll to 'Weather Alert' and press E/yes. Scroll to 1 of 7 options and press E/yes.
Alert Only - the scanner immediately sounds a weather alert siren when it detects the 1050 Hz weather alert tone, then opens the squelch and remains on the weather
channel.
SAME group 1-5 - the scanner sounds a weather alert siren for the programmed county, then opens the squelch and remains on the weather channel.
All FIPS - the scanner sounds a weather alert siren for any programmed county, then opens the squelch and remains on the weather channel.
Using Fire Tone-Out
Contents
With the tone out feature, the scanner monitors up to 10 different channels for paging tones (two-tone sequential, single tone, and group tone).
See also
Hardware: Tone-out at WPA Scanner.
Setting up Tone-Out
Press Menu. Scroll to 'Tone-Out for...' and press E/yes.
Scroll to 'Tone-Out Setup' and press E/yes.
Scroll to 'Tone-Out 1' and press E/yes.
At 'Edit Name' press E/yes. See
Entering Text.
Scroll to 'Set Frequency' press E/yes.
At 'Edit Frequency' press E/yes. Enter the frequency to monitor for tone-out and press E/yes to save and exit.
Scroll to 'Set Modulation' and press E/yes. Scroll to Auto, FM, or NFM and press E/yes to save and exit.
Scroll to 'Set Attenuator' and press E/yes. Scroll to On or Off and press E/yes to save and exit.
Press Menu to return.
http://marksscanners.com/396/396.shtml (41 of 51)8/17/2010 10:11:40 PM

Other manuals for Uniden BCD396T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uniden BCD396T and is the answer not in the manual?

Uniden BCD396T Specifications

General IconGeneral
BrandUniden
ModelBCD396T
CategoryRadio
LanguageEnglish

Related product manuals