73
3-31 GS1
DataBar (GS1 DataBar Truncated)
GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format,
except its height is reduced to a 13 modules minimum; while GS1 DataBar should have a height
greater than or equal to 33 modules.
Read:
Format
Code ID setting: Refer to Code ID setting of 3-11 UPC-A.
Insertion group selection: Refer to Insertion group selection of 3-11 UPC-A.
Conversion:
UCC/EAN 128- Refer to Code ID transmission of 3-40 String transmission, ]Cm will be identified
as AIM ID.
UPC-A or EAN-13- Barcode beginning with a single zero as the first digit has the leading “010”
stripped and the barcode reported as EAN-13. Barcode beginning with two or more zeros but not
six zeros has the leading “0100” stripped and the barcode reported as UPC-A.