121
<SW>704200
- Start read character default = STX
- Stop read character default = ETX
- This option is NOT compatible with ISCP.
Scanning / Triggering - Software Trigger - Enable
<SW>704201
Scanning / Triggering - Software Trigger - start character [STX] (02h) (*)
<SW>704302
Compose start character
Scanning / Triggering - Software Trigger - stop character [ETX] (03h) (*)
<SW>704403
Compose stop character
Turn off after good read
- When active, the scan engine stops the reading session after a successful
decoding.
- Turn off after good read is only used in the following trigger modes:
- Level
- Pulse
- Autostand
- Standard Aim
- NOTE: this parameter is NOT used with continuous and flashing modes.
Scanning / Triggering - Turn off after good read - Enable (*)