<SW>704601
Scanning / Triggering - Turn off after good read - Disable
<SW>704600
•
••
•Retrigger delay
- Only valid if "Turn off after good read" is disabled.
- This setting is a time delay in which the scanner turns off after a good read.
When the delay is done, the scanner automatically turns back on (retriggers).
- Value is in milliseconds.
Scanning / Triggering - Turn off after good read - Retrigger delay - 0 (*)
<SW>70860000
•
••
•Aimer mode
- Allows you to locate the bar code you want to read.
- The aiming beam is only used with the following trigger modes:
- Level
- Pulse
- Autostand
- Toggle*
-NOTE*: In Toggle trigger mode, "one pull aim, one pull read" does not work as
stated. Instead one pull turns on the aimer only. When the trigger is released
decoding begins. If no decode, second pull turns aimer and decoding off.
Scanning / Triggering - Aimer mode - Typical aimer (*)