PLS4.75 PLS6.75 PLS6MW
(multi wavelength)
PLS6.150D
Operating
Environment
Well-ventilated oce (recommended) or clean, light-duty manufacturing
Operating
Temperature
50ºF (10ºC) to 95ºF (35º C) capable
73ºF (22ºC) to 77ºF (25º C) for best performance
Storage Temperature 50ºF (10ºC) to 95ºF (35º C)
Operating Humidity Non-condensing
Particulate/Odor
Outside Ventilated
Exhaust System
High-pressure vacuum blower capable of:
250 CFM (cubic feet per minute) @ 6 inches
static pressure (425m3/hr at 1.5kPa)
500 CFM (cubic feet per minute) @ 6 inches static
pressure (850m3/hr at 1.5kPa)
Computer
Requirements
(See the Installation & Set-up
Guide for more information)
Windows XP, Windows Vista, or Windows 7 (32 and 64 bit)
2.0 GHz Processor (minimum)
1 GB of RAM (minimum)
40 GB Hard Drive (minimum)
Software
Requirement
Graphics or CAD based (See page 61 for recommendations)
Laser Safety
Main Laser, Interlocked Safety Enclosure = Class 1
Red Diode Pointer = Class 2