18
Cut Line Center of
Hinge
Center of Hinge
Cut Line
PULL TO OPEN - Actuator Hinge Mounting Tube Installation Dimensions
Gate opening in degrees
Ranger HD
Dimension A
Ranger HD
Dimension B
Ranger Pro80
Dimension A
Ranger Pro80
Dimension B
90 degree opening 6” 13” 5” 7½”
100 degree opening 7½” 12” 7” 7”
105 degree opening 9” 10½” 8” 5½”
120 degree opening 11 8”
6a
Dim A
Dim A
Dim B
Dim B
* Dimensions shown are
for 90° - 95° opening.
Install Actuator Mounting Tube - PULL TO OPEN (PRO80 or HD)
Cut Actuator Mount Tube to proper length. Weld to support bracket.
(See table below for desired dimensions.)
The actuator mounting tube will need to be cut so that the ” hole location matches the dimensions
for a pull to open system.
IMPORTANT: Verify the actuator type (PRO80 or HD) paying attention to the dimensions in the
chart below.