40
Emergency Manual Release
Remove the manual release pin at the gate bracket and open the gate by hand. Secure the gate
before attempting to pass through.
Manual Release Pin
Secure in place with
pull clip. Release pin
is predrilled for this
purpose.
HDPRO80
All gate operators require periodic checking and adjustments of the control mechanism for force (load),
speed and sensitivity.
All accessories and monitored safety devices must be checked. Monitored protection devices need to be
checked at least once a month for proper operation.
Periodic checking is also advised for the following:
1. Battery terminals for corrosion, clean as required.
2. Hinges and pivot points need to be greased.
3. Mounting bolts for correct tightness.
4. Inspect weld points for cracks or other defects.
5. Inspect wiring for cuts, nicks or other defects.
6. Inspect hinge post to ensure it is not moving or twisting.
7. Verify monthly that the inside of the control cabinet remains clean and free of insects. Do not spray
control board with bug spray or oil based products.
8. Observe battery controller and verify battery voltage reading is above 11 vdc. If not have battery
load tested.