46
* IMPORTANT FIRST
STEP
First thing to verify is that no monitored entrapment devices are
creating the problem.
1. Press the Open/Close button on the control board. If gate does
not operate proceed to step 2.
2. Press the Type D S4 push button and hold to operate the gate.
3. If gate operates while pressing the S4 button then a monitored
device is preventing normal operation.
4. If control board clicks and gate does not operate the battery
needs to be load tested, replace or charge as necessary.
5. Identify monitored devices connected and check for proper
operation.
1. Single gate will
not operate:
(Ranger I)
Verify monitored
entrapment device
switches are set
correctly. See installing
monitored entrapment
devices section.
1. Open the control box cover locate the “Open/Close Command” push
button and press it to operate the gate.
2. Press the “Reset” push button located above the “Open/Close
Command” button, then push the “Open/Close command” push
button to operate the gate.
3. Press and hold the “LED Indicator” push button and observe all of
the red LED’s
a. If any of the LED’s below the J2 terminal plug on the control board
are on then this must be corrected. These lights correspond to the
J2 accessory input terminals.
b. Identify the light that comes ON and then the J2 terminal number
it is associated with.
c. Locate the accessory, which is connected to that J2 terminal
number
d. Disconnect the accessory wire from that J2 terminal and verify
gate operation.
4. Call the factory for more information if the above steps have not
worked.