ENGLISH
- 63 -
PARAMETER VALUE DESCRIPTION DEFAULT MEMO
Co.tE
Test of the safety edges
This menu allows setting the method of control of the safety edges
working
no
no
Test disabled
rESi
Test enabled for conductive rubber safety edges
Foto
Test enabled for optical safety edges
riLA
Motor Release on Mechanical Stop
When the gate halts against the mechanical stop, the motor is controlled
for a fraction of a second in the opposite direction, decreasing the motor
gear tension
2
0
Function disabled
1 - 10
Time motor release (max. 1 second)
FinE
End of Programming
This menu allows to finish the programming (both default and
personalized) saving the modified data into memory
no
no
Do not quit the programming
Si
Exit from the programming menu, storing the parameters set