Vacon 20 User Manual

Vacon 20
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
vacon • 1
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
Table of Contents
Document: DPD01925A
Version release date: 30.5.17
1. Safety................................................................................................................2
1.1 Danger.................................................................................................................................2
1.2 Warnings .............................................................................................................................3
1.3 Earthing and earth fault protection ....................................................................................4
2. Modbus - general info.......................................................................................5
2.1 Restrictions .........................................................................................................................6
3. Modbus technical data ......................................................................................7
3.1 Modbus RTU protocol .........................................................................................................7
3.2 Connections and wiring ......................................................................................................7
4. Installation........................................................................................................8
4.1 Installation in VACON® 20 family AC drives ......................................................................8
4.1.1 Preparation for use through RS485....................................................................................8
5. Fieldbus parametrization ...............................................................................10
5.1 Fieldbus control and basic reference selection...............................................................10
5.2 Modbus RTU parameters and monitoring values ............................................................10
5.2.1 Fieldbus protocol ..............................................................................................................11
5.2.2 Slave address ....................................................................................................................11
5.2.3 Baud rate...........................................................................................................................11
5.2.4 Parity type .........................................................................................................................12
5.2.5 Communication timeout ...................................................................................................12
5.2.6 Reset communication status ............................................................................................12
5.2.7 Communication status......................................................................................................12
6. Communications .............................................................................................13
6.1 Modbus address area .......................................................................................................13
6.2 Supported Modbus Functions...........................................................................................13
6.3 Modbus data mapping.......................................................................................................14
6.3.1 Modbus process data in VACON® 20 Application ACCN1004..........................................14
6.3.2 Modbus process data in VACON® 20X and VACON® CP Application ACIT1075 .............17
6.4 Example messages ...........................................................................................................20
6.4.1 Example 1 - Write Process Data.......................................................................................20
6.4.2 Example 2 - Read process data ........................................................................................21
7. Fault tracing ...................................................................................................22
7.1 Typical fault conditions .....................................................................................................22
7.2 RS-485 bus biasing ...........................................................................................................22
7.3 Other fault conditions .......................................................................................................23
8. Quick setup .....................................................................................................24
9. APPENDIX 1 - PROCESS DATA ........................................................................25

Other manuals for Vacon 20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon 20 and is the answer not in the manual?

Vacon 20 Specifications

General IconGeneral
Communication OptionsModbus, CANopen, PROFIBUS, Ethernet
Protection ClassIP20
Power Range0.25 to 18.5 kW
Control MethodScalar control, Vector control
Ambient Temperature-10°C to +50°C