CONFIGURATION/PARAMETERIZATION 77
Parameter: “Speed controller”
Parameter Selection Description
Controller cycle 0 ... 9999ms Cycle time of the controller
Min. speed difference
target and actual
0 ... 999mm/s The voltage controller becomes active if the measured speed
is within these limits.
Max. speed differ-
ence target and actu-
al
0 ... 999 mm/s
Speed correction fac-
tor
0 ... 100% The max. value for which the speed can be adjusted (±).
Min. controller volt-
age
0 ... 100% Minimum output voltage from the controller in % of the nor-
mal output voltage.
Controller step width,
frequency
0 ... 1200Hz/10 Frequency change per controller step
Controller step width,
voltage drop
0 ... 200%x0.5 Voltage change per controller step

Table of Contents